EXCELLENCE IN CONSTRUCTION AWARDS – COMMERCIAL                         2021 IEC NATIONAL AWARDS



































              COMMERCIAL CONSTRUCTION CATEGORY B
              TUTOR ELECTRICAL

              SERVICE INC.


              IEC Fort Worth/Tarrant County

              Rowlett Fire Station No. 2 & Emergency Operations Center







            The 2021 nominees: Bret’s Electric for Nelnet Rampart Remodel, Bret’s   Due to the constraints of the municipal bond package funding this project, Tutor
            Electric for Temple Grandin Equine Center, Central Electric for SAISD   Electrical Service, Inc. initiated a scope refinement process to drive value into the
            Davis MS Renovations, DeRock Electric Company for Metso Minerals   project and reduce the overall cost of the electrical scope of work. Over the course
            Office Renovation, Independent Mechanical Inc. for Two Doughboy,   of three months, every design component was evaluated to identify areas where
            R&A Enterprises for Aspen Street Lodge, Titan Electric Georgia for   cost savings could be generated without sacrificing the needs of the end users.
            Emory Sports Clinic and Tutor Electrical Service, Inc for Rowlett Fire
            Station No. 2 & Emergency Operations Center.        Significant savings were gained through a completely re-imagined approach
                                                                to the incoming electrical service and power distribution system. Initially, the
            In April 2020, Tutor Electrical Service, Inc. was selected to provide   design team had settled on a 1,600A, 120/208V, three-phase system due to
            subject matter expertise and real-time cost data as a member of   concerns over available floor space for transformers if a 480V system was
            the design team tasked with conceptual development of a new Fire   installed. Tutor Electrical Service, Inc. was able to demonstrate that an 800A,
            Station and Emergency Operations Center for the City of Rowlett,   480Y/277V system was a more cost-effective solution, and that concerns
            Texas. The project would include a 4,200 sq. ft. fully-enclosed concrete   about available floor space for the electrical system were unwarranted.
            storm shelter within the Fire Station structure to house an Emergency
            Operations Center, Network MDF Room, Main Electrical Room, and   Additional savings were generated from the building lighting systems by
            Dispatch. The project would also include a separate building to house   adjusting fixture counts, lumen levels, and substitution of alternate fixture
            specialty fire apparatus for water rescue, a brush fire truck, and other   types, without sacrificing design aesthetics or required foot-candle levels.
            accessories. The site development would incorporate an existing   Also, at the request of the Fire Chief, integrated, processor-based lighting
            regional emergency communication radio tower, a modular fire training   controls were replaced with localized line-voltage switching for cost
            tower, and remote power pedestals to service fire apparatuses and   savings and ease of use. In total, the cost savings generated by the
            ambulances visiting the site for training. Tutor Electrical Service, Inc for   "value-engineering" efforts allowed the overall project electrical budget
            Rowlett Fire Station No. 2 & Emergency Operations Center.  to be reduced by approximately 22%.



                                                                 www.ieci.org | November/December 2021  | Insights Magazine  23